No person shall. erect or re-erect any building on any ground which has been filled up with offal or offens ive vegetable or animal mailer or upon which any such matter is deposited, unless and until tho Medical Officer of Health certifies that such matter has been properly removed by excavation or otherwise has become or been .rcndered innocuous.
'[40. Structural Design. - The structural design of foundation masonary timber plan concrete, reinforced concrete, pre-stretched concrete and structural steel, shall be carried out in accordance with part VI Struotural Design, Section I - Loads Section-2 - Foundation, Scction-J - Wood, Section-4 - Masonary Sectjon-5-Concrete, Section-6-'Steel oflhe National Building Code of'India, laking into consideration all relevant Indian Standrds prescribed by the Bureau of Indian Standards including the Indian Standards given in Annexure 'A' for earth quake protection OfbUildi~.]
'[41. to 49. Deleted.
'[SO. Thickness of alis. - All structural.external and partywalls exposed to weather/protected from weather built ofbrieks ofblocks laid illhorzontal bed..
or courses shall be constructed of thickness 1I0t less than 28 ems. upto three storied buildings with maximum height not more thun 10.5 meter. The thlekness of . .- --------_ .- .- ---------- - --- I. Sec PI!.capital(Dev, & Rell.) tluir,t;"g (Amendment) Rules, 1993 (22.:.,1993)
2. Sub>. "ide eM. Admn, 0117_ No,lncallon No. ~1JI10!63-UTFt(j)-2001/4011 Ill. 16-5-2DOt p.
1027 punjab Capital (Development and Regulation) Building Ru les, 1952, (I) Only oiie servant 100m shall be: built on a site:of'size 420 sq. rnts. or more , . ' in area.
(ii) For one dwelling unit, only one servant room shall be provided.
(Iii) If a servant room is built 011 II ground fluor i1 shall have a separate courtyard of not less than 10 sq. mts, (Iv) Separate servant room not built as part of the main house shall have a wate r closet and bathroom attached thereto.
(v) 1111~ maximum covered area of a servant room shall not exceed 12 sq.
mts. excluding water closet and bathroom.] .
'[33. Advertisement stand ami structure; - No structure shall be CO Il structed to carry all advertisement except in the area shown on the zon ing plan!
architectural control sheet/standard design.] ,
34. Numbering ofbuildings» Each building shall bear a number in aCCOr dance with the type designs which shall be: made available by the ChiefAd min is trator and shall bear IIU other number;
I [35. Dust Bin. - Every person who creels or re-erects a bui lding, shall provide a dustbin which shall conform in size, shape, specifications and to a type ofdesign to be made available by the ChiefAdminlstrator.l . PARTlY Material and Struetul'lIl C\lnlrul Section 1 . • Materials '[,56.All material to be used for the erection or re-erectlon of'a building shall conform to the specification and-standard laid down In part V of the Nat ional BuiJdingCode oflndiaon Building Material.]
'[37. LJeleted.]
,' [311. Deleted.] ,, 60 Punjab Capital (Development and Regulation) Building Rules, 1952 walls shall be determined in accordance with the relevant provisions ofNational Building Code of India, incase buildings with height more tan to.5 M.]
I [51. to 59 Deleted.]
'[60. Applicatlon: (i) Chimneys where provided shall conform to the re- ' quircments of IS 1645 - 1960 Indian Standard Code of Practice for Fire Safety of Iluild ing (General) Chimney's flues, Flue pipes and Hearths.
(ii) Notwithstanding the provisions lor clause (i) above a chimney shaft shall be built 1.8 M high above the roof ill the case or approachable terraces used for sleeping purposes and within the heights ofthe parapet-in other cases. In the case , ofs!oping roofs, the chimney shaft shall not be less than 0,6 M above the ridge of -.
the roof in which it penetrates. ' .
(iii) Chimney shafts shell be provided with a set back of0.9 M from the front and rear of the building in all cases and also from the external side in the case of corner plots.]
1[61. to 69. Deleted.]
1[70:Floor. - (i) All floors laid on ground shall be so constructed or treated as to prevent damp rising by capillary action into the floor. In all cases oflayer or 10 Crus. of clear sand shall be provided between the earth and tho hard crust.
(ii) Every kitchen, latrine, urinal, bathroom or a bathing platform, shall have impermeable floor and all kitchens, in addition to impermeable, shall have fire prooffloors. . , ' .
(W) TIH~ walls of every wafer,closet upto a height of not less than sixty centimetres (60 Cms.c) above jho floors shal! be finished in an' impervious material.] " . . . _ . . - . .
1(71. Roofs. - The roof of a building shall be so constructed as to be fire resisting, weather proofand non-crodable.]
"' ......
. 1[72. Staircase ill residential bllildilzgs, sillglefamily or Iwofamily rest dential bllill/illes. - Every building more than one storey high intended to be used as residential building shall be provided with atleast one staircase having minimum width of 85 ems. with rise of not more than 19 crns., limited to 15 Nos. per flight and tread not less than 25 ems. in width constructed of tire resisting rnaterials.]
*** 1(73. Residential buildings for more than two families, - Every building intended to be used as residential building for more than two families shall be provided with atleast one staircase extending from ground floor level to the high est floor having minimum clear width in accordance with the following width in accordance with the following table :- " (a) Number of users upto 10 85 ems.
(b) Number of users upto II to 20 .1.10 meters
(c) Number of users from 21 to 100 1.25 meters
(d) Increase 1fI (2.5 cms.) for every additional 15 persons until a maximum of2.75 in. is reached.
'Asingle staircase ofwidth mentioned above may be replaced by two stair case each ofawidth atleast equal to two-thirds the width prescribed for a single staircase provided neitherofother two substituted staircases be less than 1.1 m in width. Staircase so provided shall be built in fire resisting materials.
(0) Occupant Load:
---------_.----.._--- - ----------~--------------_._------- --------------- : . S.:" pt;. ::::"pilaJ (Dev. & Reg.) (}uilL;llii ~'\lncnd;;lJllt) Rules, ! 993 (22-1-:993) , .
62 Punjab Capital (Development and Regulation) Building Rules, 1952