A Drive-in-Cinema shall be constructed so as to confirm to the follo," ing r\.'quirements, namely:- {lJ A Drive-in-Cinema shall have a road frontage on a pub1ic throughfare upon which the site of such cinema abuts and m such frontage, there shall be a suitable provbion for entrance and exist for motor cars.
At the entrance, sufficient space shall be provided for motor cars waiting to enter the premises. The space shall be sufficient to hold at least 1/5 of the total capacity of motor cars in the Drive-in-rinema and at least two st.:parate entry bays w1lh ticket booths shall be provided for entry of such cars into area. Minimum two gates for exit for motor cars shall be provid,.d where the cinema is constructed to accommodate more 'than 600 motor cars. The width of each of the entrance and exit gates shall not be Jess than 4 meters.
(2) On the boundaries of the Dnve-in-Cinema either a compound wall of fire-resisting material with a height of not less than 2 meters above the le\'e] of the ground adjoining the wall \\ ithin the comiJound shall be constructed or the whole compound shall be surrounded by a barbed wire fer.cc and a hedge of bushes.
(3) The entrance and exit area shall be adequately lighted by floodlights.
. (4) The lateral limitation of the spectator area shall be co.1fined to an u.ngle of 35° with respect to the centre line of the screen.
(5) 111c rows of motor cars facing the screen shall be provided in the form of an arc of a circle with its centre at a distance of 0.6 breadth of the screen, at the back of thl! screen on the centre line.
(6) The distance between the screen and the front row of vehicles shall not be Jess then 1.5 times the width of the picture on the screen.
(7) The width of one bay accommodating motor cars in a row faring the screen shall not be less than 12 meters. ·
(8) A clear passage of not less than 12 meters in width shall be provided on either side of the spectators' area.
(9) In all the rows of motor cars the front of the motor cars shall stand higher than the area to ensure that from the area a complete view of the screen is visible.
(10) The size of the picture projected on the screen shall be as sryecified below, namely:- { I) For 200 to 400 motor cars Height 11 meters; width 25 meters; bottom 6 meters above the ground,
(2) For 401 to 600 motor cars Height 13 meters, width 30 meters; bottom 7 meters above the ground,
(3) For 60 l to 1000 motor cars Height 19 meters; width 43 meters; bottom 8 meters above the ground.
( 11) The screen shall be so located that it is not lighted by sunset or by the evening twilight. It shall be constructed with concrete material or steel frame.
(12) The screen shall be so constructed as to with stand wind velocity of 160 kilometers per hour or a pressure of 120 kilograms per square meter. The screen shall be inclined slightly forward. The maximum inclinal1011 shall be 8° with the vertical axis.
( 13) The screen or a part thereof shall not be visible from road side.
( 14) Red warning limits shall be mounted at the highest points of the screen and flood lights to light the specter area shall be mounted over it.
4-10 GUJARAT GOVERNMENT GAZE'ITE EX,. 7-1-2014 (PART IV-B
(15) The motor car bays shall be uniform by 12 meters wide or 12 meters and 8 meters wide alternatively:
Provided that, the first 4 rows shall have 12 meters wide bays.
( 16) Loud speaker poles shalJ be provided to serve one motor car each on either side. The distance between the two poles in a ro'' shall not be less than 6 meters. The poles or loud speakers shall not be embedded in a concrete base and shall have a light over them so as to indicate their position. The light shall be at the side of the poles turned away from the screen which shall also illuminate the row and place number:
Provided that, it shall not be necessary to provide a pole with loud speaker for each motor car if alternative arrangement is made for the transmission of sound to the satisfaction of the licensing authority:
Provided further that, in any case the distance between any two motor cars standing along side in the same row shall not be less than two meters.
( 17) Separate arrangement for lighting of the rows showing the numbers or the places shall be made.
(18) The projection room shall be located in close building in the centre of the premises. Such projection room may be a part of the structure accommodating public toilet, canteen, kitchen shops and such amenities, sufficient care shall be taken to see that the light from these structures does not all on or, obstruct the proper viewing of, the projection. Where car bays are provided at the back of the projection room also, the area shall be so elevated that proper view is obtained of the screen.
CHAPTERV ELECTRIC INSTALLATION