the Gujarat Cinema Rules, 2014State Rules of Gujarat · 2004
(1) All conductors including lead covered cables where accessible to the public shall be efficiently protected from mechanical injury by an external armour of iron steel.
(2) Where conductors pass through or within walls, fire- proof floors or ceilings, they shall be protected by iron pipes or by glazed stoneware or porcelain tubes aud precautions shall be taken to prevent the possibility of fire or water passing along the course of the conductors.
J
PART-IV-B] GUJARAT GOVERNMENT GAZETIE EX,. 7-1-2014 4-13
(3) Conductors shall not be placed at such place where liable to be heated by jets steam pipes or other appliances.
( 4) In special cases, or where necessary for protection from the depredations of rats, mice or other vennin, the wiring shall be enclosed in heavy gauge steel conduit.