No building, or veranda, or balcony or projection in any building shall be permitted to be erected, re-erected, added to or altered in any case where the distance between such construction and any overhead electric lines, in accordance with the provision of the Indian Electricity Act, 1910(9 of 1910) as amended time to time, and the rules made there under, is less than that specified hereinafter: - (“m” indicates metre) Vertical Clearance Horizontal Clearance
(a) l_ow and Medium voltage lines 25 m. 12 m.
Including servnce lines
(b) High Voltage lines up to and including 11.000 volts 3'7 m' 1'2 m'
(c) High voltage lines above 11.000 volts and up to 3.7 m. 2.0 m.
and including 33 K.volts.
Page 32
(d) For extra high voltage lines 3.7 m. plus 0.3 m for 2.0 m plus 0.3 m for beyond 33.000 volts every additional 33.000 every additional 33 K volts or parts thereof. volts or parts thereof.