CourtMesh

Section 12: Particulars to be furnished in, and with, an application

The West Bengal Municipal (Building) Rules, 2007State Rules of West Bengal · 1993

(1) Every application made under rule 11 shall be written on a printed form (to be supplied by the Municipality) and shall state the location of the site, reference number of approval of the site plan, the number assigned to the premises in the assessment book and its dimensions, and such other particulars as may be specified by the Board of Councillors.

(2) All site plans, building plans, elevations and sections shall be on drawing sheets which shall be in any of the sizes specified in the table below:— 12 THE KOLKATA GAZETTE, EXTRAORDINARY, FEBRUARY 14, 2007 [PART I TABLE Drawing Sheet sizes Serial No. Designation Trimmed Size mm 1 AO 990 x 1198 2 A 1 594 x 990 3 A2 495 x 594 4 A3 297 x 495 5 A4 247 x 297 6 A5 148 x 247

(3) The plans may be ordinary prints of Ferro-paper or other paper or blue printed or generated print, but one set of such plans shall be blue printed. Prints of plans shall be in the manner specified in the table given below:— TABLE Si.

No.

Item Site Plan Building Plan White Plan Blue Plan Amonia Print White Plan Blue Plan Amonia Print

1. Plot Lines Thick Black Thick Black Thick Black Thick Black Thick Black Thick Black

2. Existing Street Green Wash Green Wash Green Wash Green Wash Green Wash Green Wash

3. Future street if any Green Dotted Green Dotted Green Dotted Green Dotted Green Dotted Green Dotted

4. Permissible Building Lines Thick Dotted Black Thick Dotted Black Thick Dotted Black Thick Dotted Black Thick Dotted Black Thick Dotted Black

5. Open Spaces No colour

6. Existing Work Yellow Yellow Yellow Yellow Yellow Yellow

7. Work proposed to be demolished Yellow ' Hatched Yellow Hatched Yellow Hatched Yellow Hatched Yellow Hatched Yellow Hatched

8. Proposed Work Red Filled in Red Filled in Red Filled in Red Filled in Red Filled in Red Filled in

9. Drainage and sewerage work Red Dotted Red Dotted Red Dotted Red Dotted Red Dotted Red Dotted

10. Water supply work Black Dotted thin Black Dotted thin Black Dotted thin Black Dotted thin Black Dotted thin Black Dotted thin

11. Deviations Red Hatched Red Hatched Red Hatched Red Hatched Red Hatched Red Hatched

12. Recreation Ground Green Wash Green Wash Green Wash Green Wash Green Wash Green Wash

(4) The plans shall be coloured as specified in Table of sub-rule (3).

(5) Building plans, elevations and sectional elevations shall be drawn to scale of 1 : 100 and 1 : 200 for Plans, in case of sites whose area exceeds 2000 square metres.

(6) The plans, sections (longitudinal and sectional) and elevations of building shall indicate and show:— A. For buildings upto 14.5 m. height— (al the floor nlims of flnnrc including roof plan together with the covered area;

existing bui"'-gs the sizes of rooms and slLzs and spacings of structural members and their materials;

4,b)

PART I] THE KOLKATA GAZETTE, EXTRAORDINARY, FEBRUARY 14, 2007 13

(c) the location of essential services, that is to say, water closet, sink, baths, septic tank and the like, and arrangement for drainage or sewerage and other waste water disposal including sewer connection, if any;

(d) the sizes of footings, the thickness of basement walls, other walls, floor and roof slabs, the construction materials, sizes and spacing of framing members, floor to ceiling heights, parapet heights with their materials, taking at least one fully dimensioned section (both longitudinally and crosswise) through staircase, bath and water-closet as well as such other sections as would clearly indicate the details of architectural features, mezzanine floors, and lofts;

(e) the front elevation and all other elevation from the abutting public streets;

(f) the house drainage plan and site drainage plan up to nearest Municipal outfall or natural outfall;

(g) the dimensions of all projected portions beyond the permissible building line;

(h) the roof plan indicating the drainage and slope of the terrace; showing position of Rain Water pipes;

(i) the plans and details of private water-supply and sewerage disposal system, if any;

(j) (i) the details of breast wall, retaining walls or other protective measures, if any, which are required to be undertaken;

(ii) no part of the proposed building shall be permitted to be erected directly over the retaining or other similar protective walls;

(k) where structural design or soil stability and similar other tests are necessary for a building under any provision of these rules, the copy of details of reports and/or recommendations of soil stability or other tests and/or copy of details of calculations for structural design duly signed by the competent personnel as specified in rule 15 or rule 161 (for Municipalities in hill areas).

B. For buildings exceeding 14.5 metres in height— The building plan shall, in addition to the provision of sub-rule (1) also show:—

(a) special requirements as to access, circulation, building services and safety, human health and Fire based on occupancies or use group as laid down in National Building Code of India, and in the West Ben.

West Bengal Fire Services Act, 1950; Act XVIII of 1950.

(b) parking layout plan showing parking spaces, driveways together with ingress or egress arrangements;

(c) width of main and alternate staircases along with balcony approach, corridor, ventilated lobby approach;

(d) location and details of lift enclosures;

(e) location and size of fire lift;

(f) smoke-stop lobby or door, where provided;

(g) details of exits including provision of ramps in the case of hospitals and for special risks;

(h) location of smoke exhauster and fan;

(i) location of smoke exhauster in basement;

(j) details of fire alarm network;

(k) location of centralized control connecting the alarm system, built-in fire protection arrangements and public address system;

(1) location and dimensions of static water storage tank and pump room along with fire service inlets for mobile pump and water storage tank;

(m) location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, drenchers and carbon dioxide installation;

(n) location and details of first aid equipment;

(o) special requirements, if any, of occupancies for residential building, educational building, institutional building, assembly building, business building, mercantile building, storage building, industrial building and hazardous building under these rules;

(p) location for installation of a sub-station for electric supply, transformer, generator and switch gear room,

(q) location of the air-conditioning plant room, if any;

(r) plan for in o'qtion of boilers, if any;

(s) refuse chip -s and refuse chamber, if any;

(t) location for signs and outdoor display structures, if any;

(u) conveniences for physically challenged personnel.

14 THE KOLKATA GAZETTE, EXTRAORDINARY, FEBRUARY 14, 2007 [PART I

(7) Doors and windows schedule shall show sizes of doors, windows, and frames.

(8) The plan in its headline shall indicate specifically,—

(a) the purpose of construction,

(b) the name of the owner,

(c) the name of the police-station, and

(d) the name and jurisdiction list number of the mouza and cadastral survey or revisional settlement number of the plot or plots of the site, if required.

(9) The nearest road of 3 metre width or more with the pathway connecting the road and the site should be shown in case of plot abutting roads less than 3 metre.

(10) In case of addition, alteration or reconstruction of old buildings, which were constructed prior to enforcement of any building rules in the concerned area without the approval of any authority, in addition to the documents, as stipulated in this rule, structural stability certificate as per provisions of sub-rule (1) of rule 170 shall be submitted with the building plan, and in all such cases the sanction shall be made as per the provisions of these rules.

Where this provision sits

ActThe West Bengal Municipal (Building) Rules, 2007
Section12
Marginal noteParticulars to be furnished in, and with, an application
JurisdictionState of West Bengal
StatusIn force as published by the source

Find the provision, not just read it

The full text above is free, and it stays free. What a free CourtMesh account adds is everything you cannot do by reading one page at a time:

  • Search 49,000+ Central and State enactments by what a provision says, not by its number
  • Jump from any section to every judgment that has applied it
  • Search 300 million+ Indian court records alongside the statute
  • Ask a research agent to find and read the case law on a provision for you

Free account. No card. About a minute to create.

Create a free account

Need this as data, not as a page? The West Bengal Municipal (Building) Rules, 2007 is one of 49,000+ enactments on CourtMesh. The Indian court cases API serves the case law that cites these provisions over JSON, with API documentation and plans and pricing. See also the judgment library.