(1) The building used for the manufactory shall be constructed with brick or stone and the roof of the building shall be of reinforced cement concrete or Madras Terrace or shall be of non-inflammable material.
(2) All windows, ventilators and sky lights in the building other than those in the ware-house and store room shall be fitted with rods spaced not more than 10 centimeters apart, centre, to centre. All the windows, ventilators and sky lights in the ware-house and store room shall be covered with galvanized wire net or square mesh, not more than ½ centimeters apart.
(3) All the doors which are to be fitted with excise ticket locks shall be free from tampering of the hinges from outside.
(4) All doors fitted to the building shall open outwards.
(5) There shall be no thatched shed with in the manufactory or ware house compound.
(6) All the openings in the external walls intended for the efflux of waste water shall be covered with grills affixed to the wall.
(7) There shall be separate rooms or compartments isolated by grills embedded in cement concrete provided for the following purposes and no such room or compartment shall be used for more than one of the said purpose:-
(a) manufacturing;
(b) storage of wine in build and bottling operation;
(c ) Storage of wine in sealed bottles, casks, barrels and other receptacles.
(8) There shall be separate tanks for fermentation, storage and fortification.
12
(9) Each tanks used for fermentation, storage or fortification shall be marked with a permanent serial number and the capacity of such tanks accurately gauged by the Department of Weights and Measures under the Standard of Weights and Measures (Enforcement) Act, 1985 (Central Act 54 of 1985).
(10) Every room or compartment in the manufactory shall be well-ventilated and shall bear on the outside a sign board denoting the purpose for which the compartment or room is used for.
(11) All gas and electric connections with the manufactory shall be fixed in such a manner as to ensure that the supply of gas or electricity can be cut off and all the regulator or switch shall be securely locked at the end of each day‟s work.
(12) Unless, otherwise directed by the Commissioner in writing, there shall be only one entrance and one exit to the manufactory and one emergency exit and one door to each of its rooms or compartments. All the doors which are provided shall be secured with excise ticket locks. The emergency exit doors shall be kept closed with the excise ticket locks and shall be opened only on emergency occasion.
(13) Necessary air condition arrangements shall be made within the manufacturing unit as may be specified by the Commissioner from time to time.
(14) Necessary Fire Extinguishing equipment shall be kept in the manufacturing unit.