(1) Every Lift well intended for the installation ofthe Lift or any equipment necessary for its maintenance shall be exclusively reserved for that purpose and shall not be used for any other purpose;

(2) The inner sides ofa Lift well shall, so far as practicable, form a smooth, continuous flush surface devoid of projections or recesses. Where any projections extending inwards from the general surface ofthe enclosure at or near openings or landing cannot be rendered flush, then they shall be leveled on the underside to an angle ofnot less than 60 degree from the horizontal by means ofmetal plates, cement rendering, or other suitable fire resisting materials.

(3) Where there is more than one Lift in common well, a width ofminimum allowance of 100 millimeters for separator beam shall be made.

(4) Where there is more than one Lift in common well, a suitable separator screen throughout the whole height ofLift well having adequate strength shall be fixed in the Lift well to protect the person working in the Lift well or in the Lift car, from accidental contact with counter weights and other Lift car at any state of their travel.

(5) No room, passage or thorough fare shall be provided under any Lift well except in case of the Lift having counter weight fitted with over speed governor safety device.

(6) Where a Lift car leveling device is operative with the Lift car gate opening such interior surfaces shall always form a smooth flush surface below each landing level for a depth to at least the depth ofthe car leveling zone plus distance through which the Lift car may travel of its own momentum when power is cut off.

(7) Sufficient space shall be provided between the guides for the car and the side walls ofthe Lift well enclosure to allow safe and easy access to the parts of the safety gear for their maintenance and repairs.

e 14 TIIEKOLKATAGAZETIE,EXTRAORDlNARY, NOVEMBER 11, 2022 [PARrI

(8) Every Lift well, together with the whole ofthe equipment and apparatus contained therein, shall be rendered fire resisting to the greatest possible extent.

(9) A notice with the word "Lift" shall be placed on the outside of each landing door.

(10) (10) The Lift well shall conform to specifications laid down by Bureau of Indian Standards specification BIS-14665 (Part-1)-2000.

Where this provision sits

ActThe West Bengal Lift, Escalator And Travelator Rules, 2022
Section24
Marginal noteLiftwells
JurisdictionState of West Bengal
StatusIn force as published by the source

Find the provision, not just read it

The full text above is free, and it stays free. What a free CourtMesh account adds is everything you cannot do by reading one page at a time:

  • Search 49,000+ Central and State enactments by what a provision says, not by its number
  • Jump from any section to every judgment that has applied it
  • Search 300 million+ Indian court records alongside the statute
  • Ask a research agent to find and read the case law on a provision for you

Free account. No card. About a minute to create.

Create a free account

Need this as data, not as a page? The West Bengal Lift, Escalator And Travelator Rules, 2022 is one of 49,000+ enactments on CourtMesh. The Indian court cases API serves the case law that cites these provisions over JSON, with API documentation and plans and pricing. See also the judgment library.